AquaMaster revolutionizes high
volume water measurement. Available in sizes 5/8" to 24", the rugged
AquaMaster is designed to maximize revenue collection by offering a broad
flow range with high accuracy, retention of high accuracy without testing or
parts replacement, low-cost, foolproof installation, optional data logging
capability and battery or mains-powered models to accommodate site
requirements.
Model H4300 is a Woltman-design
horizontal impeller meter, with only two moving parts, the impeller and
magnet. The H4300, in sizes 2" h to 6", is a high accuracy turbine meter,
operating with low flow accuracy ±3% and accuracy ±1% up to peak flow. The
H4300 is recommended for measurement up to 250° F and pressure up to 230 psi.
Either a reed switch element or opto-electronic pulse transmitter can be
selected for the H4300.
The M150, sizes 1'' and 1½'', is
a multi-jet inferential impeller meter with NPT inlet and outlet. The M150
is designed for batch or continuous process monitoring of hot water up to
195° F and services up to 150 psi.
PVDF Turbine,
sizes ½'' and 1'' is designed for those applications where a more rugged
meter is required. This unit retains all of the capabilities of the AMCO 316
SS Turbine Meter, plus the PVDF (Kynar) material and ceramic shaft allow use
with approximately 100 more chemicals than stainless steel.
sizes ½'' to 2'' for flows from 0.5 gpm to 1500 gpm,
address a wide range of industrial and commercial fluid measuring
applications. Meters can operate in high pressure (up to 1500 psi)
applications.
AMCO Electronics /
Accessories
Return
to
PRODUCTS page
R420 W 4-20mA
Designed to operate with any AMCO
meter with a pulser, the R420 provides rate indication, totalization and
4-20 mA DC analog output signal proportional to the flow rate.
The industrial
Electronic Register is an
LCD display that has been installed in a
watertight, aluminum housing easily
adapted for installation on AMCO C700,
T3000 and H4000 cold-water meters.
The ER is designed to replace
mechanical
registers with LCD displays
of rate indication and totalization in the basic
unit.
This index is also resettable.
Inline Strainers
Vertical Z-plate design strainers
are recommended to protect AMCO T3000 and C3000 cold-water
meters from the
damaging effects of debris and foreign material. The strainer improves the
velocity
profile of the water being metered and minimizes the effects of
velocity distortion caused by upstream
valves and fittings. Strainers are
for use in potable cold water up to 120° F and working pressure up
to 150 psi and should be installed immediately upstream from the meter.
+/- 1% Over 10:1 Turndown & +/-
0.5 Repeatability
Flow Rates to 20 GPM (76 lpm)
Mechanical Direct Reading Register, 99.9 Gallons or 999 Liters
1" Ports
NPT or BSP Ports Standard
Aluminum Case
PPS Measuring Chamber
EPR Seals
95 PSI (6.5 BAR) MWP
TS Series
Liquid Flow
Meters
MODEL / SIZE / GPM
TS10 (1") 4-40 GPM
TS15 (1-1/2") 6-60 GPM
TS20 (2") 10-150 GPM
TS30 (3") 20-200 GPM
NTEP Approved TS Series
Materials & Performance
NTEP Approved (+/- 0.175% Over 5:1 Turndown & +/- 0.05%
Repeatability)
Flow Rates to 200 GPM (760 lpm) Mechanical or Electronic Registers with Optional Preset & Printing Functions
1", 1½", 2", & 3" Models (All Sizes Are Not Approved in Every Market or With
Every Option)
Companion Flanges Standard, 150# RF ANSI Adaptors Optional
Anodized Aluminum or Stainless Steel
316 Stainless Steel Shafts
PPS Rotors with Carbon or Teflon™ Bearings
Viton™ or Teflon™ Seals
400 PSI (28 BAR) MWP with Electronic Register
150 PSI (10.5 BAR) MWP with Mechanical Register
Complete Range of Accessories
Strainer, Air Eliminator & Air Check Valve for Refined Petroleum Products
Strainer, Vapor Eliminator & Differential Valve for LPG Service
Mechanical Preset Valve with Linkage
1-State & 2-Stage Solenoid Valve
+/- 1%
Over 10:1 Turndown & +/- 0.5% Repeatability
Capacity to 0.5 GPM (1.9 lpm) with 50:1 Turndown
Choice of Fiberoptic or Dual Hall Effect (Equal Quadrature) Pulser
Pulse Output +/1 30,000 PPG (+/- 7,925 ppl)
3/8" AN Ports
Case: 303 Stainless Steel
Gears: Hardened Stainless Steel
Bearings: Tungsten Carbide
Shafts: Tungsten Carbide
Teflon™ Seals
5000 PSI (345 BAR) MWP
Electronic Large Numerical Counter (ELNC)
Materials & Performance
6 Digit
Reset Total, 1" (25 mm) Numerals and Programmable Decimal Point
8 Digit Non-reset Totalizer, 3/8" (9.5 mm) Numerals, Whole Units Only
NEMA 4X Enclosure (Equiv. to IP67), Powder Coated Aluminum
4 Power Options
Internal Batteries (Two 3.6V Lithium C Cells)
External 12 or 24 VDC Power
External 110 or 220 VAC Power
ELPC-2057 Power Supply/Barrier (To Satisfy Intrinsically Safe Standards)
K Factor Range: 1.00 to 9,999
Temperature Range: -20°F/+158°F (-28°C/+70°C)
Optional Rate/Minute Display (Alternates with Reset Total, Toggle Via Reset
Button)
Optional Scaled Pulse Output (1 or 10 Pulses/Unit)
Optional Back lighted Display
Optional Built-In Heater for Use to -40°F (-40°C) Ambient Temperature
5 Digit
Reset Total, 3/8 " (9.5 mm) Numerals and Programmable Decimal Point
8 Digit Non-reset Totalizer, 0.2" (5 mm) Numerals, Whole Units Only
NEMA 3R, NEMA 4X, or NEMA 7/4 Enclosure
Internal Battery Powered with One 3.6V Lithium AA Cell
K Factor Range: 1.00 to 9,999
Temperature Range: -40°F/+158°F (-40°C/+70°C)
Optional Rate/Minute Display (Alternates with Reset Total, Toggle Via Reset
Button)